Disposable 24 Hours/72 Hours Closed Suction Catheter

Products Details

Closed suction catheter standard form 

Size

Color Code

Type

O.D.(mm)

I.D.(mm)

Length(mm)

6

Light Green

Children

2.0±0.1

1.4±0.1

300

8

Blue

2.7±0.1

1.8±0.1

300

10

Black

Adult

3.3±0.2

2.4±0.2

600

12

White

4.0±0.2

2.8±0.2

600

14

Green

4.7±0.2

3.2±0.2

600

16

Red

5.3±0.2

3.8±0.2

600

1.The unique design of closed suction tube has proven effective in preventing infections, reducing cross-contamination, reducing intensive care unit days and patient costs .
2. Providing Quality Solutions for RESPIRATORY CARE.
3. Sterile,individual PU protective sleeve of closed suction system can protect the caregivers from cross  infection.With isolation valve for effective VAP control.
4. Individually wrapped to stay fresh.
5. Respiratory Suction system with  sterilization by EO gas,latex free and for single-use.
6. Double swivel connectors reduce strain on ventilator tubing.
-Packaging Details -Packing: 1pc/sterilized pouch, 10pcs / inner box, Outer packing: 100pcs / shipping carton -Delivery Time: Within 30 days. It depends on quantity of order * Prevent the VAP in ventilated patients * Dual swivel elbow offers convenience of rotatability for optimal comfort. * Atraumatic, soft catheter minimizes the damage to mucosal membranes. * Clear depth markings to limit the distance of catheter for safe suctioning. * Thumb control facility at the proximal end prevents inadvertent suctioning. * With ports for flushing and MDI administration. * Day stickers which easily identify change requirements. * Medical grade PVC, LATEX-FREE. * 24Hours/72Hours version available.1. Soft and kink resisting tubing; 2. Color coding for size identification; 3. With closed tip or opened tip depending on different request; 4. Be blister packing; 5. Be sterilized by EO gas. 6. Easy operation and less trauma caused to patients 7. Peer pouch or hard tray unit packing 8. easy for operation and learn, convenient for widely applicIt is used to suck up sputum and secretion from patient's airway.Manufacturer of Closed Suction Catheter for Medical Use Good Quality & Excellent Service ISO & CE Certified Adult/Pediatric for 24Hr and 72Hr Professional Manufacturer1. Plastic suction catheter, slide valve for positive pressure, transparent plastic film and commutation switch and three-way connectors compose a closed suction catheter, 2. This product changed traditional open operation it avoided medical staff infection to the patient for respiratory tract in the surgery, 3. It adopts many closed design and add the clean connector, 4. It can out of danger from the gas patients breathe and infection of secretion into the catheter. 1. Closed suction catheter set consists of a three-way valve, a control box Assembly and a suction catheter, 2. The suction catheter extends from the three-way valve to the control box and is covered in the film.The three-way valve has distilled water delivery port for cleaning after use, 3. When in use ,the three-way valve connects to an endotrachael tube through patient port and a ventilator through the breathing port, 4. Control box button activates suctioning and suction catheter can be inserted or retracted through the three-way valve into patients airway, 5. The catheter is graduated for easy identification of depth of insertion. 1) The smart design of the closed suction catheters allows the patients' breath-mechanical ventilation and suctioning simutaneously. 2) Push switch and Luer lock. This design can keep breathing and isolate the turbulent cleaning chamber, prevent spray back, which reduces the risk of VAP ( ventilator - associated pneumonia) for ventilated patients. 3) Prevent cross infection. The closed suction systems are designed with protective sleeve to isolate the germs inside the patients and avoid cross infection to caregivers. 4) Soft and smooth blue suction tip. This design reduces damage to mucous membranes. 5) Double swivel connectors reduce strain on ventilator tubing. 6) Easy operation in suction process by being equipped with a wedge (seperator) to disconnect and clip functions. 7) For tracheostomy tubes. The suction catheters match tracheostomy tubes, different tube length available. The catheters are marked with accurate depth to understand the proper catheter insertion in the trachea. The closed suction catheter system is an advanced design, it allows patients comfort of suctioning without stopping the air ventilation. The PU protective sleeve can protect the caregivers from infection. The design of push switch and Luer lock can reduce the risk of VAP for ventilated patients. * Allow for suctioning a patient on a ventilator without loss of PEEP or mean airway presure. * Reduce oxygen desaturation by allowing constant patient ventilation. * Reduces the potential of infection to the clinician. * Maintains a sealed airway to reduce exposure to secretions. * Eliminates patient “Spray Black”. * Provide maximum suction and is designedto reduce trauma. * Enhance patients safety avoids disconnectionfrom the ventilator during catheter change-out or untangling of lines * Decrease accidental extubation ordecannulation during moving of the patient. * Color coded rings provide fast size recognition. * Original blue soft head. * Color: White or transparent or blue.Closed Suction Catheter consists of plastic suction catheter, slide valve for positive pressure, transparent plastic film and commutation switch and three-way connectors compose a closed suction catheter. This product changed traditional open operation it avoided medical staff infection to the patient for respiratory tract in the surgery. It adopts many closed design and add the clean connector. It can out of danger from the gas patients breathe and infection of secretion into the catheter.Reanson 1: Prevention of hypoxemia and atelectasis The closed suction tube greatly reduces the occurrence of hypoxemia without interrupting the ventilation and oxygen supply, especially in critically ill patients with poor tolerance to hypoxia. Reason 2: Prevention of exogenous infection Traditional sputum suction steps are cumbersome and complicated. Any step of aseptic operation technique is not strict, and items are not sterilized directly, which can directly cause secondary infection of lower respiratory tract and increase the incidence of nosocomial infection. The closed sputum suction tube has simple operation steps and blocks bacteria from outside. Reason 3: Prevention of cross infection Traditional sputum suction requires disconnecting the ventilator, and the patient's irritating cough can cause respiratory secretions to spew out, pollute the surrounding environment and nurses, and cause cross-infection among patients in the same ward. Closed sputum suction is carried out in a closed condition, which reduces the chance of cross infection and ensures the safety of

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours